Numerous US utility companies promote residential energy conservation via rebate programs, frequently reacting to state-level energy reduction requirements or the strategic goal of lowering demand to avoid expanding generation infrastructure. A core presumption of these incentive initiatives is that the most energy-inefficient homes are the most likely to use these rebates; however, this paradigm does not always hold. The primary objective of this research was to assess the viability of prioritized incentivization—specifically, ranking incentives to maximize energy conserved per dollar invested across an entire municipality. This investigation employs a data mining methodology that utilizes established structural and energy attributes to forecast the power usage of homes, which together serve as a representative sample of all dwellings within a given community. Using this model, the study calculates natural gas usage, potential savings, and the associated implementation costs of implementing the most effective energy conservation strategies. These projected savings and expenditures enable the creation of a phased energy mitigation strategy, targeting the most economically advantageous interventions throughout the entire utility service area. Findings indicate that a 36% reduction in energy usage is attainable at a levelized expense of under $14 per mmBTU ($14,780 per MJ), illustrating the robust efficacy of this methodology. A parallel Economic Input–Output Analysis delineates the ripple effects this strategy has on the local economy. The analysis reveals that across approximately 45,000 single-family homes in the examined area, a preliminary $26M expenditure on energy efficiency could generate an aggregate multiplier economic effect of $41M, alongside supplementary economic benefits of $2.2M over the lifespan of the evaluated efficiency improvements.
In 2015, the United States building sector accounted for 45% of the nation’s CO2 emissions [1]. There is an established target to decrease energy consumption in both residential and commercial building domains by at least 35% before 2030 [2]. In recent times, focusing on community-wide building energy conservation has garnered substantial interest, as it offers distinct avenues to accomplish energy efficiency and integrate renewable energy sources from various standpoints [3-9]. Several prior investigations have explored community-level trajectories for curtailing energy usage [10-15]. While these analyses demonstrated that behavioral modifications, minimized air infiltration, combined insulation and infiltration strategies, and extensive retrofitting yielded prospective energy conservation, their projections relied on generalized presumptions concerning residential energy profiles. One investigation assessed multiple Energy Efficiency (EE) frameworks designed to enhance EE, noting fluctuating levels of uniformity in their execution and success. This research determined that demand-side administration could generate annual energy savings of 4 quads and a carbon mitigation of 63 million metric tons per year [16]. Koomey et al. [17] leveraged building sector data from diverse repositories to formulate policy models aimed at augmenting EE, projecting that a rigorous EE initiative could produce energy conservation and carbon emission reductions of 20% and 40%, respectively, by the year 2025.
Contemporary research has predicted building thermal and cooling requirements through the application of data mining methodologies [18-22]. Neural networks (NN) are extensively employed to project the energy consumption of structures [23]. Findings indicated that while solar radiation and ambient temperature exerted a profound influence, other variables could be excluded from the forecasting models. Certain analyses have integrated Bayesian NN approaches to evaluate building energy utilization, incorporating standard environmental variables as inputs [24-28]. Artificial neural network (ANN) systems were applied to predict the energy performance of residential structures, utilizing diverse environmental attributes as input factors and overall energy expenditure as the output metric [29]. Table 1, presented below, catalogs antecedent efforts by researchers who applied machine learning methodologies to forecast residential energy utilization. This tabular summary details the respective researchers, the specific techniques employed, the predictive variables used, the targeted consumption metrics, and the accuracy of the resulting forecasts.
Table 1. Document of prior research in predicting energy consumption in residential buildings.
Study/Prediction method | Building/Energy system characteristics | Input variables | Target variable | Prediction output | Performance metric |
(Aqlan et al., 2014)/Artificial Neural Network (ANN) with cluster analysis | Not specified | Dry-bulb temperature, relative humidity, and solar irradiance | Annual energy demand | Annual energy consumption | Root Mean Square Error (RMSE) = 0.031 |
(Chae et al., 2015)/Artificial Neural Network (ANN) | Commercial buildings with HVAC temperature set-point schedules | Day-type classification, time of day, outdoor dry-bulb temperature, and outdoor humidity | Historical energy-use records and hour of the day | Electricity consumption at 15-minute intervals and daily peak electricity demand | Coefficient of determination (R²) = 0.902; Coefficient of Variation (CV) = 8.5% |
(Karatasou et al., 2005)/Artificial Neural Network (ANN) | Not specified | Ambient temperature, solar radiation, relative humidity, and wind speed | Building load demand | Hourly building energy loads | Mean Bias Error (MBE) = 0.13 |
(González-Vidal et al., 2016)/Bayesian Regularized Neural Networks and Random Forest | Not specified | Historical hourly data including outdoor temperature, humidity (%), solar irradiance, wind speed, wind direction, dew point temperature, and vapor-pressure deficit | Daily energy-use data | Daily energy consumption forecasting | Coefficient of determination (R²) for both methods ranged from 0.65 to 0.75 |
(Fan et al., 2014)/Eight widely used forecasting algorithms | Not specified | Commercial-building energy consumption records and meteorological information | Building power-consumption data collected at 15-minute intervals | Next-day energy consumption and peak power demand prediction | Mean Absolute Percentage Error (MAPE): 2.32% for next-day energy consumption and 2.85% for peak power demand |
Enhancing the economic efficiency of utility-sponsored energy reduction initiatives by directing rebate funds toward homes with the highest potential for savings has been the primary motivation behind several recent studies. An evaluation of the financial advantages of EE enhancements for dwellings in the Desert region was conducted utilizing discrete building energy simulations to forecast the yearly electrical conservation and return-on-investment timelines for multiple upgrades, facilitating the creation of a financially viable EE rebate strategy [30]. A comparable investigation [31] leveraged accessible residential structural information alongside historical energy metrics for homes in a US Midwestern locale to pinpoint properties poised to generate maximum savings from distinct interventions; nonetheless, their evaluations relied upon somewhat debatable premises. For instance, the researchers posited that elevated weather-normalized heating energy consumption in a given home correlated with uniformly inadequate wall and attic insulation, subpar window thermal performance, and inefficient heating systems. In practice, however, the energy efficiency of these distinct architectural elements is often not homogeneous. The complete lack of attic insulation, as an example, could act as the nearly exclusive cause for a dwelling’s excessive energy utilization.
The financial advantages of EE extend beyond the monetary savings realized by individual homeowners, encompassing broader community impacts such as employment generation and augmented local disposable income. Along these lines, one investigation established a methodical architecture to measure the municipality-wide repercussions of residential EE expenditures [32]. Using an Economic Input–Output Analysis focused on Montgomery County, Ohio, the authors found that a $14M capital injection into residential heating, ventilation, and air conditioning (HVAC) systems could generate an aggregate economic ripple effect of $22M. Briefly, a machine learning paradigm is deployed to construct a unified model capable of predicting the thermal requirements across diverse residential properties. The outcomes revealed that the projected conservation aligned with the realized savings to within a 2.5% margin for the majority of the energy efficiency strategies evaluated in the research.
Figure 1 illustrates the operational framework implemented in this investigation. Initially, information was gathered to forecast the power requirements of individual residences. The subsequent phase involved computing deduced energy attributes derived from longitudinal monthly natural gas consumption and meteorological records. The third procedure aimed to isolate the variables exerting the most substantial influence on energy utilization by applying a Random Forest (RF) algorithm. The fourth operation focused on formulating a singular NN architecture to predict the energy consumption metrics for every dwelling. In the fifth stage, both singular and aggregated energy conservation potentials were calculated. The sixth phase sought to corroborate the anticipated savings utilizing a k-nearest neighbors (KNN) computational method. The seventh process estimated the most economically viable energy enhancement alternatives by deploying a “worst-to-first” prioritization scheme. The final step quantified the broader municipal economic consequences stemming from the strategic energy efficiency capital allocations derived from the study’s findings. The subsequent sub-sections elaborate on the intricacies of each phase of the research.

Figure 1. Eight research steps of proposed framework.
This study was facilitated by access to an aggregate cluster of more than 500 residential structures utilized as student accommodations, which are the property of a university in the Midwestern US. These dwellings exhibited considerable diversity regarding dimensions (ranging from 66 to 258 square meters of floor space), construction age (spanning from almost 100 years to merely 2 years), and energy efficiency. The variance in energy performance primarily stemmed from incremental renovations executed on the properties over the preceding fifteen years. The dataset compiled for this analysis encompassed the accessible historical monthly electrical and natural gas consumption records for these properties. Furthermore, during the summer of 2015, the academic institution executed energy audits across 139 of these dwellings, which recorded details concerning building envelope insulation, window specifications, resident occupancy, kitchen appliances, HVAC systems, domestic hot water infrastructure, and the presence or type of basements. Lastly, real estate documentation from the county auditor supplied comprehensive structural data for every dwelling. Table 2 displays the maximum and minimum parameters of the architectural data. For example, the empirically assessed wall thermal resistance, Rwall, ranged from 0.7 to 2.43 m2K/W; the attic thermal resistance, Rattic, varied between 1.14 and 7.1 m2K/W; and furnace efficiency levels fluctuated between 60% and 95%.
Table 2. Residential house characteristics achieved from the energy audit.
Characteristics | Max | Min |
Afloor (m2) | 258 | 66 |
Awall (m2) | 302 | 54 |
Awindow (m2) | 27 | 7 |
Aattic (m2) | 245 | 43 |
Attic penetration area (cm2) | 3716 | None |
Basement duct vent area (cm2) | 348 | None |
Rattic (m2K/W) | 7.1 | 1.14 |
Rwindow (m2K/W) | 0.35 | 0.18 |
Rwall (m2K/W) | 2.43 | 0.70 |
Rbasement (m2K/W) | 0.88 | 0.70 |
Occupants (number) | 12 | 2 |
Efficiency of furnace (%) | 95 | 60 |
Water heater (energy factor) | 0.96 | 0.55 |
Seasonal energy efficiency ratio (SEER (AC)) | 16 | None |
Figure 2 depicts the extent of variability within the recorded geometrical attributes of the structures, revealing substantial fluctuations across the floor, wall, window, and attic spaces of the residences.

Figure 2. Histograms showing the variation of the building characteristics.
Figure 3 displays the variability among distinct energy parameters, including Rattic, Rwindow, and Rwall, alongside the efficiency of the furnace heating apparatus, water heating unit, and AC SEER rating. Evidently, except for Rwindow (Figure 3b), every characteristic exhibited marked variance.

Figure 3. Histograms for the effectiveness of energy efficiency measures.
A random forest algorithm is employed to pinpoint specific geometric and energetic traits of the buildings (acting as predictor variables), aiming to determine the most relevant structural elements for incorporation into the neural network (NN) framework. This methodology was initially introduced in a previous investigation [33] addressing both regression and classification challenges. The formulated random forest model integrated the input Ai/Ri, wherein Ai and Ri represent the surface area and thermal resistance of the building envelope components, respectively. While infiltration rates might be measured through blower door assessments for every evaluated home, acquiring these metrics on a large scale would be financially prohibitive and logistically impractical. Consequently, the current investigation incorporates those structural predictors attainable through standard post-construction property evaluations, routine real estate transactions, and accessible longitudinal energy records for each dwelling.
Moreover, to maximize the utility of existing energy metrics for forecasting the natural gas utilization of individual homes, and recognizing the robust performance of regression models correlating energy to temperature within NN frameworks, this research evaluated three supplementary attributes as potential predictive variables. These encompass the heating slope, HSgas (W/K); the weather-independent gas intensity E_(baseline, gas, i) (MJ/m2); the heating temperature balance point temperature, Tbalh, gas (°C), which denotes the mean thermal threshold below which artificial heating is initiated; and the weather-independent electric intensity, E_(baseline, electric), (kWh/m2). These natural gas metrics were derived utilizing a three-parameter regression technique (the Prism method) [34], aligning the monthly gas utilization (MJ/month) with the mean external temperature T_outside (°C) throughout the measurement duration. Here, the variable H represents the Heaviside function, as delineated in Eq. 1.
(1)
The electrical metric, , along with the cooling slope 〖 (Wh/K), were generated through an analogous three-parameter regression analyzing monthly electrical use against the mean monthly external temperature [34], structured as follows:
(2)
A fundamental premise here is that weather-independent electrical utilization introduces supplementary thermal energy into a structure, thereby exerting a measurable influence on the overall natural gas demand. The energetic consumption variables evaluated within the random forest algorithm are detailed in Table 3, which delineates the relative significance of every predictor in forecasting energy use.
Table 3. Predictors for gas consumption ranked by influence on energy consumption.
Order of variable importance (most to least important) | Predictors |
1 | Heating slope, HSgas (W/K) |
2 | Wall area/Rwall (W/m2K) |
3 | Baseline electric intensity (Baselinee) (kWh/m2) |
4 | Tbalh,gas (°C) |
5 | Furnace efficiency () (%) |
6 | Attic area/Rattic (W/m2K) |
7 | Floor area (m2) |
8 | Window area/Rwin (W/m2K) |
9 | Energy factor for water heater (EF, WH) |
10 | Maximum occupancy |
11 | Attic penetration area (cm2) |
12 | Basement duct vent area (cm2) |
13 | Basement duct vent open |
14 | Rbasement (m2 K/W) |
Figure 4 illustrates the natural gas usage predictors, ordered according to their impact on overall energy utilization. The findings indicate that the gas heating slope exerted the most substantial effect on energy demand (evidenced by a greater magnitude). In contrast, factors such as attic penetration area, Rbasement, and the state of basement duct vents demonstrated a weaker correlation with energy use (lower magnitude). Consequently, these less impactful variables were excluded from the neural network framework detailed in the subsequent section.

Figure 4. The variable importance shown by the random forest approach.
Artificial neural networks (ANN) are widely implemented across diverse energy modeling contexts. The primary benefit of employing an ANN lies in its capacity to process nonlinear dynamics [35]. The current research deployed a feed-forward ANN architecture to correlate energy consumption with the geometric dimensions and thermal attributes of residential dwellings identified as highly significant. The objective was to create a single, generalized ANN framework capable of forecasting natural gas utilization for any given residence, rather than generating distinct models for each specific property. Table 4 itemizes the input variables determined to hold the highest predictive value for energy consumption, as derived from the random forest analysis, and also specifies the targeted output metric. In total, the dataset comprised 11 distinct data features that served as inputs.
Table 4. The data used in ANN model construction.
Parameter | Model input | Model output |
Awindow /Rwindow (W/K) | X | |
Awall /Rwall (W/K) | X | |
Furnace efficiency (%) | X | |
Wall thermal conductance, (A_{wall}/R_{wall}) (W/K) | X | |
Furnace efficiency, (\eta_{fur}) (%) | X | |
Water heater energy factor | X | |
Base electrical energy intensity (kWh/m²) | X | |
Occupancy count (number of residents) | X | |
Gas heating slope, (HS_{gas}) (W/K) | X | |
Heating balance-point temperature (°C) | X | |
Mean monthly outdoor air temperature (°C) | X | |
Monthly natural gas consumption (MJ/month) | X |
Table 5 displays comparative data between two distinct residences. The informational samples were segregated into dual classifications: one representing the heating period (spanning October to April) and another encompassing the remainder of the annual cycle. The heating season grouping, serving as the central focus of this investigation, contained an aggregate of 973 samples.
Table 5. Example of data inputs for ANN model construction.
Parameter | *House Sample #1* | *House Sample #2* | ||||||
Oct. | Nov. | … | Apr. | Oct. | Nov. | … | Apr. | |
Afloor (m2) | 104 | 104 | … | 104 | 124 | 124 | … | 124 |
Aattic /Rattic (W/K) | 23 | 23 | … | 23 | 42 | 42 | … | 42 |
Awindow /Rwindow (W/K) | 53 | 53 | … | 53 | 50 | 50 | … | 50 |
Awall /Rwall (W/K) | 192 | 192 | … | 192 | 174 | 174 | … | 174 |
Furnace efficiency, (%) | 95 | 95 | … | 95 | 70 | 70 | … | 70 |
Water-heater energy factor | 0.55 | 0.55 | … | 0.55 | 0.63 | 0.63 | … | 0.63 |
Baseline electricity intensity (kWh/m) | 65.88 | 65.88 | … | 65.88 | 60.81 | 60.81 | … | 60.81 |
Occupancy level (number of residents) | 6 | 6 | … | 6 | 5 | 5 | … | 5 |
Heating slope, HSgas (W/K) | 3.77 | 3.77 | … | 3.77 | 3.77 | 3.77 | … | 3.77 |
Heating balance-point temperature (°C) | 14.72 | 14.72 | … | 14.72 | 19.63 | 19.63 | … | 19.63 |
Mean monthly outdoor temperature (°C) | 10.67 | 4.97 | … | 10.67 | 10.67 | 4.97 | … | 10.96 |
Output: Monthly natural gas consumption (MJ/month) | 5811 | 13,34 | … | 16,68 | 5811 | 17,75 | … | 19,90 |
The established deep learning ANN framework consists of a networked array of nodes, bridging input and output layers via intermediate hidden nodes. Every individual node executes a mathematical operation to convert incoming data into a modified output signal. The numerical weights assigned to these network linkages are autonomously adjusted to reduce the discrepancy between projected outcomes and empirical targets. During model development, 70% of the dataset was allocated for training, 15% was reserved for testing, and the remaining 15% was used for validation. The optimal outcomes, characterized by the highest correlation coefficient (R2), were achieved using a comparatively straightforward neural architecture containing dual hidden layers (each possessing 11 nodes) alongside a tanh activation function.
To evaluate the statistical validity of the forecasted values, a paired-samples t-test was executed to contrast the projected aggregate gas usage against the empirically recorded gas consumption. The established null hypothesis for this assessment posited that the mean values of the observed and modeled datasets were dissimilar. The t-test outcomes, presented in Table 6, demonstrate no statistically significant variation between the paired data sequences. This analytical review confirms that the statistical means of both arrays were highly comparable; furthermore, the resulting probability score of 0.921 signifies a lack of meaningful divergence between the two sets at the predetermined 0.05 level of significance.
Table 6. Two-sample t-tests for actual vs. predicted.
Data category | Number of samples | Average value | Standard deviation | Standard error of the mean | 95% confidence interval for the difference | Estimated difference | t-statistic | P-value |
Measured values | 139 | 1206 | 383 | 32 | (−85.53, 94.63) | 4.54 | 0.1 | 0.921 |
Forecasted values | 139 | 1202 | 380 | 32 | — | — | — | — |
The computational model formulated in this investigation demonstrated a robust capacity to project natural gas demand. Figure 5 illustrates a specific set of findings regarding the prediction of yearly thermal energy use across a residential sample group. Within this visualization, the empirically recorded consumption (blue) is juxtaposed against the forecasted usage (orange) for every respective home.

Figure 5. Actual and predicted annual natural gas consumption for a random sampling of houses for the October 1–April 1 study period.
As highlighted in the preceding segments, the thermal performance attributes of the evaluated dwellings exhibit broad variability. While certain properties underwent renovations across various timeframes, distinct pre- and post-retrofit metrics were unrecorded for discrete dwellings. Consequently, a “nearest neighbor” methodology was deployed to corroborate the energy reductions linked to these enhancements [36]. This analytical technique isolates the highest-probability upgraded dwelling within the broader housing clusters. Specifically, a K-nearest neighbor algorithm served to verify the conservation outcomes across six sample properties. To measure the proximity or ‘closeness’ between a modified dwelling and an unmodified counterpart, researchers utilized a Euclidean squared distance parameter—calculated as the sum of the squared discrepancies between the traits of the analyzed home and its closest matching peer. This differential error is formally expressed as:
(3)
Where n is the number of inputs, fu,j is upgraded energy characteristics, and fc,j is current energy characteristics.
Within Figure 6, six target dwellings slated for renovations are evaluated to substantiate potential conservation outcomes by benchmarking them against properties that already possess augmented thermal profiles. Following the theoretical application of distinct interventions—such as enhanced window systems and supplemental attic or wall insulation—the subsequent power demands of these homes were verified. This was achieved by juxtaposing the algorithmically forecasted post-retrofit energy usage against the empirical consumption of the corresponding nearest neighbor property. The primary variables leveraged to establish these nearest neighbor pairings consisted of the most critical structural and empirical energy predictors identified by the ANN framework: specifically, Afloor; Awall; Awindow; Aattic; Rattic; Rwindow; Rwall; # of occupants; water heater EF; heating system efficiency. Correlating the ANN’s projected post-intervention energy utilization with the authentic usage of the post-upgrade K-nearest neighbor revealed highly consistent alignments between the neural network’s forecasts and the actual operational demands of the matched homes. Because the Euclidean divergence linked to the optimal nearest neighbor remains comparatively minimal, the discrepancy between the nearest neighbor methodology and the ANN’s conservation projections is similarly narrow.

Figure 6. Comparison of predicted natural gas usage by ANN model with nearest neighbor method during winter season.
The outcomes derived from the implemented case analysis are delineated in this segment, reflecting the concluding phases of the established methodological architecture (i.e., steps 6–8).
Once the predictive reliability regarding historical energy usage was confirmed, the calibrated neural network was subsequently applied to explore prospective conservation benefits stemming from targeted retrofits. This calibrated model facilitates such explorations by generating novel informational samples, rooted in empirical data sourced from properties that have already undergone thermal enhancements. Table 7 details the specific interventions evaluated. These encompass the installation of wall and attic insulation, the integration of triple-paned window systems, water heater modernization (achieving an EF of 0.96), and furnace replacements (reaching 95% efficiency). The assigned thermal resistance parameters (R-values) for the wall and attic insulation enhancements stand at 2.28 and 7.04 m2K/W, respectively.
Table 7. The upgraded data used in ANN model construction.
Variable | Empty cell | Input |
Rattic (m2K/W) | 7.04 | |
Rwindow (m2K/W) | 0.53 | |
Rwall (m2K/W) | 2.28 | |
Furnace efficiency, (%) | 95% | |
Energy factor for water heater | Instant | 0.96 |
Storage | 0.70 | |
Heating slope, HSgas (W/K) | Calculation | |
Heating balance point temperature (°C) | Calculation |
Recognizing that the heating slope, HSgas, and heating temperature balance point, Tbal,h, served as foundational inputs for defining energy usage profiles, and acknowledging that architectural renovations would alter these variables, it became imperative to project the post-retrofit shifts in these metrics. The adjustment to the heating slope was executed by noting that HSgas can be mathematically represented as:
(4)
Where Ai is the envelope feature area (wall, window, or attic), Ri is the associated thermal resistance, and is the furnace efficiency. Should either the mechanical efficiency or the thermal resistance figures be modified, the resulting HSgas will correspondingly shift, as demonstrated within Eq. 5.
(5)
The structural heating temperature balance point, Tbal,h, is intrinsically linked to the heating slope to some degree. In scenarios characterized by an elevated heating slope, thermal dissipation from the dwelling becomes perceptible to occupants even at comparatively moderate external temperatures. Conversely, as efficiency interventions successfully suppress the heating slope, the corresponding temperature balance point will concurrently drop.
At this specific balance point threshold, the internal thermal gains of the dwelling are computed utilizing Eq. 6.
(6)
Following the execution of the efficacy upgrades, the revised Tbalh, gas, upgrade metric can be ascertained via Eqs. 7–10.
(7)
(8)
) (9)
(10)
Where is the thermostat set-point temperature.
The parameterized data reflecting the renovated dwellings were subsequently processed through the established ANN architecture to evaluate valuable energy savings. The energy reductions yielded by specific residential retrofits are calculable via Eq. 11.
(11)
Where and are the total energy consumed for the current and improved house, respectively.
The prospective energy mitigation generated by deploying discrete EE strategies across a single winter cycle was estimated. The mean cold-season conservation metrics across the comprehensive residential dataset are presented in Table 8. As the findings explicitly demonstrate, the proportional natural gas reductions stemming from supplemental wall insulation vastly outperformed the benefits derived from both window modernizations and attic insulation additions, a disparity primarily driven by the fundamentally poor current state of insulation within the studied structures.
Table 8. Average natural gas savings from individual upgrades.
Parameter modified | Wall thermal resistance ((R_{wall})) | Attic thermal resistance ((R_{attic})) | Window thermal resistance ((R_{window})) | Furnace efficiency | Water heater energy factor |
Mean natural gas savings | 27,657 MJ | 4,842 MJ | 5,380 MJ | 3,874 MJ | 2,690 MJ |
Mean percentage reduction in energy use | 21.3% | 3.7% | 4.14% | 2.95% | 2.08% |
Table 9 illustrates the prospective natural gas conservation attainable through the execution of aggregated EE interventions. The data indicate that enhancing the building envelope yields a more substantial impact than replacing water heaters and furnaces because existing mechanical systems are already reasonably efficient, and replacement costs exceed those of envelope enhancements. Consequently, these findings underscore the necessity for a more optimized, strategic EE enhancement framework, which is detailed in subsequent sections.
Table 9. Comparison of energy savings from different combinations of upgrading options.
Retrofit Scenario | Annual Energy Reduction | Energy Reduction (%) |
Building envelope improvements only | 33,253 MJ | 25.62% |
Building envelope improvements combined with furnace upgrade | 34,760 MJ | 26.82% |
Building envelope, furnace, and water-heater upgrades combined | 35,513 MJ | 27.37% |
Leveraging the capacity to precisely project energy cost reductions across diverse EE interventions for all homes within the residential dataset, a tiered investment strategy was formulated. A levelized cost of savings indicator ($/MJ) was employed to establish this prioritization [37]. For these calculations, the operational lifespan of the investment was projected at 20 years for furnace and water heater modernizations, and 30 years for the remaining weatherization upgrades [38]. Additionally, the baseline fuel price and the yearly energy cost inflation rate were set at 0.6 $US/therm and 3%, respectively. To evaluate financial feasibility, a minimum attractive rate of return (MARR) of 7% was established as the baseline for project acceptability.
Table 10 presents the estimated expenditure for system enhancements, sourced from existing literature [31].
Table 10. Implementation cost of the EE measure.
Energy-efficiency upgrade measure | Cost per unit |
Wall insulation enhancement | $7.9/m² |
Attic insulation enhancement | $7.5/m² |
Window replacement/upgrade | $226/m² |
Heating system upgrade | $19/m² |
Water-heating system upgrade | $19/m² |
Applying Eqs. 1–6 alongside the projected energy conservation for each EE intervention, the levelized expenditures were computed individually for each dwelling. Figure 7 illustrates the outcomes if all dwellings within the dataset received maximal-efficiency retrofits (indicated in green), contrasting these figures against the ‘break-even’ investment threshold established by McKinsey [37]. As depicted, solely the expenditure associated with wall insulation enhancements proved more advantageous than the McKinsey benchmark. This suggests that the proportional natural gas conservation derived from supplemental wall insulation substantially exceeded the savings generated by window modernizations or attic insulation installations. Furthermore, it demonstrates that indiscriminate capital allocation toward arbitrary EE interventions across the broader housing stock fails to yield financially viable cost-effectiveness.

Figure 7. The annual energy savings for various measures vs. average levelized cost savings ($/MJ).
Figure 8 delineates the distribution density of the levelized cost of energy conservation across all homes for every evaluated efficiency strategy. These findings highlight the heterogeneous thermal performance characteristic of the analyzed housing inventory. The data reveal that the financial threshold to achieve savings via wall insulation upgrades represents the lowest among all evaluated conservation strategies. This underscores the significantly higher financial utility of prioritizing interventions with lower levelized costs.

Figure 8. Histograms of levelized cost of energy savings ($/GJ).
Figure 9 provides an alternative viewpoint on the LCFS across the residential cohort, modeling a scenario where the intervention possessing the most favorable levelized cost is executed initially, followed sequentially by the next most economical option. The LCFS for every evaluated strategy is plotted in ascending progression relative to its economic efficiency. These outcomes explicitly demonstrate the financial prudence of establishing an investment hierarchy. The minimum LCFS figures for specific EE strategies fall beneath the established McKinsey benchmark. Additionally, the analysis reveals that particular investments harbor the capacity for broader implementation across the housing portfolio. To illustrate, fewer than 5% of the homes exhibit LCFS metrics for furnace and water heater upgrades that sit beneath the benchmark (a consequence of atypically elevated energy usage in those specific dwellings), whereas 78% present financially sound opportunities for wall insulation enhancements.

Figure 9. LCFS of EE measures for all residences (cost effectiveness shown in ascending order).
The cumulative levelized expenditure for deploying an EE intervention across k dwellings is defined in Eq. 12.
(12)
The implementation penetration rate of this specific intervention within the housing dataset, relative to these cumulative savings, is calculated as 𝑘∕𝑁 × 100, where N represents the aggregate count of homes.
While the preceding segment utilized a “worst-to-first” paradigm for isolated interventions, this portion investigates the phased integration of strategies across the comprehensive suite of measures to identify the most optimal LCFS. Figure 10 displays the outcomes of this approach, plotting the cumulative LCFS against the proportional natural gas reductions. Executing a single EE enhancement generates a ripple effect that influences the efficacy of subsequent efficiency upgrades. For instance, while adding wall insulation immediately augments the structure’s thermal performance, it simultaneously diminishes the prospective conservation yields of an independent furnace modernization, given that the improved envelope has already curtailed the baseline energy demand. Figure 10 illustrates the feasibility of slashing energy consumption by 36% up to the benchmark LCFS limit of $14/mmBTU ($14,782/MJ) [37], underscoring the robust viability of this methodology.
Furthermore, it indicates that deeper energy reductions require substantially higher capital expenditures (reflected in the exponential segment of the curve). As an example, achieving a 38% drop in natural gas usage requires an investment of $20,115/MJ, while pushing for greater reductions mandates an exorbitant capital outlay that lacks financial justification. Consequently, the juncture where the LCFS trajectory shifts abruptly signifies the absolute threshold of cost-effective conservation achievable via present-day EE technologies.

Figure 10. Aggregated LCFS for all houses as a function of percentage energy reduction.
Figure 11 demonstrates the pathways to attain varying magnitudes of energy conservation through the implementation of this “worst-to-first” methodology. As depicted, enhancements to wall insulation exerted the most profound influence on realizing targeted energy reductions. The data suggests that as the overall proportion of energy mitigated expanded, the absolute conservation derived from wall insulation enhancements grew concurrently. Conversely, the cumulative energy conservation generated by the remaining interventions was comparatively minor.

Figure 11. Scenarios for achieving various levels of energy reduction using “worst-to-first” approach.
Table 11 presents the community-scale proportions of natural gas conservation, the yearly reduction in energy expenditures, and the requisite capital to subsidize each EE strategy evaluated within this research. Across all EE interventions, the break-even LCFS threshold of $14/mmBTU ($14,782/MJ) established by McKinsey serves as the benchmark for computing the percentile of natural gas conservation [37]. To illustrate, an aggregate 36% of natural gas usage can be mitigated while maintaining an LCFS beneath the $14/mmBTU ($14,782/MJ) limit across the evaluated measures.
Table 11. Savings and investment for achieving LCOS $14/mmBTU ($14,782/MJ) from EE measures.
Retrofit option | Share of natural gas reduction | Yearly monetary savings ($) | Capital investment ($) |
Wall insulation retrofit | 0.48 | 16,024 | 117,967 |
Attic insulation retrofit | 0.35 | 4,647 | 83,514 |
Window retrofit | 0.10 | 2,707 | 59,703 |
Furnace replacement | 0.10 | 1,846 | 26,928 |
Water-heater replacement | 0.10 | 1,806 | 27,111 |
To quantify the ripple effects on the local economy, this investigation merged an economic input–output (EIO) architecture with granular municipal datasets. EIO analysis systematically delineates the direct, indirect, and induced economic consequences of capital allocations across a broader market. For instance, a drive to augment residential EE inherently boosts the manufacturing output of industries producing those efficiency materials; this constitutes the direct impact. This initial capital injection subsequently stimulates elevated output among ancillary suppliers delivering necessary raw materials and logistical services (representing the indirect impact). This surge in both primary and secondary production frequently translates into new employment opportunities or higher wages. Subsequently, this expansion in household disposable income is often recirculated within the municipality through expenditures on recreation, education, and various local services (encapsulating the induced impact).
While a comprehensive theoretical breakdown of the IO paradigm falls outside the purview of this paper, the Leontief IO model [39] functions as the foundational architecture for this analysis. The Leontief framework treats fluctuations in final demand as exogenous variables, computing the necessary adjustments in gross industrial output to maintain equilibrium between supply and demand across all market sectors. A primary premise of the classical Leontief structure is the static direct requirement matrix A, which denotes the fractional monetary input a specific sector demands to generate a single dollar of market output. Stated differently, these input coefficients signify the monetary contributions from sector i essential to yield $1 of production in sector j, based upon the established financial transaction matrix. This matrix is customarily deployed to evaluate shifts in the aggregate production vector (x) triggered by alterations in the final demand vector (y), as modeled in Eq. 13:
(13)
Where A constitutes the n × n direct requirement matrix, y represents the financial valuation of the final demand column vector, x is the aggregate monetary industrial production column vector, and v functions as the monetary value-added row vector. Table 12 catalogs the ten industrial domains within Montgomery County, OH (the locale of the evaluated properties) that have garnered the most significant economic benefits from residential wall insulation capital allocations. While the leading three sectors experienced direct surges in commercial transactions and service demands stemming from these capital injections, the remaining industries were similarly stimulated via indirect and induced economic pathways. The former—indirect or supply-chain repercussions—are primarily linked to vendors supplying base materials to those top three sectors; notably, these impacts appear relatively muted within the local municipality, implying that a majority of essential manufacturing components are sourced externally.
Table 12. Top 10 industries impacted by local wall insulation investment.
Economic sector / Industry category | Economic output |
Architecture, engineering, and associated professional services | $60,882 |
Manufacturing of fiberglass insulation materials | $29,495 |
Production of thermal insulation and polystyrene foam products | $29,493 |
Imputed rental services for owner-occupied residential properties | $5,462 |
Food service establishments and beverage providers | $3,943 |
Private healthcare and hospital services | $3,317 |
Real estate service providers and establishments | $3,211 |
Central banking, monetary authorities, and deposit-based credit intermediation | $2,707 |
Wholesale trade sector | $2,657 |
Telecommunications services | $2,637 |
Additional 430+ industrial sectors | — |
As demonstrated by the other seven industrial categories, the compounding financial influence of wall insulation expenditures inherently encompasses induced economic activity. For example, personnel employed at insulation manufacturing plants might inject their augmented earnings—derived from the heightened demand for EE materials—back into the local ecosystem via residential leasing, healthcare utilization, and increased consumption of food and beverages. An identical analytical protocol was applied to the remaining EE strategies, with Figure 12 detailing the proportional distribution of direct, indirect, and induced community-level economic consequences linked to each investment.

Figure 12. Breakdown of local economic impact by EE investment.
Table 13 summarizes these compounding economic repercussions.
Table 13. Economic impacts of EE installation to the community.
Economic indicator | Wall insulation | Attic insulation | Window upgrade | Furnace upgrade | Water heater Upgrade | Total value |
Direct effect contribution | $117,968 | $83,515 | $59,704 | $26,928 | $26,928 | $315,043 |
Indirect effect contribution | $27,078 | $20,105 | $13,117 | $6,093 | $6,093 | $72,486 |
Induced effect contribution | $37,737 | $29,560 | $20,806 | $10,122 | $10,122 | $108,347 |
First-year monetary savings | $16,024 | $4,647 | $2,707 | $1,846 | $1,846 | $27,070 |
Ten-year cumulative monetary savings | $160,235 | $46,465 | $27,068 | $18,462 | $18,462 | $270,692 |
The profound relevance of these findings becomes particularly clear when projecting the data across the City of Dayton, which contains slightly more than 45,000 single-family dwellings structurally analogous to the evaluated sample. To realize the designated 36% contraction in energy usage, an upfront EE capital allocation of $26.1M would be necessitated; however, the subsequent compounded economic ripple effect would generate an estimated $41.2M. Furthermore, the retained capital resulting from these thermal efficiency upgrades would stimulate a supplementary economic impact totaling $2.21M over the operational lifespan of the implemented strategies.
The advanced methodological framework seeks to isolate the most financially viable energy conservation interventions, facilitating their phased implementation while prioritizing strategies that utilize accessible—or ascertainable—structural and energetic metrics across a broad portfolio of single-family dwellings. An ANN architecture is deployed to project natural gas conservation alongside the levelized expenditures for a wide array of potential structural efficiency upgrades. Empirical machine learning forecasting systems have traditionally relied on easily procured datasets, encompassing variables such as meteorological records, resident occupancy rates, and sociodemographic profiles. Few antecedent studies have integrated granular structural properties, primarily due to the logistical hurdles of acquiring such data at a macro (regional) scale. The formulated analytical architecture permits the projection of both baseline energy utilization and the prospective conservation attainable through the execution of discrete EE interventions. This model operates using a constrained array of verifiable architectural parameters—including geometric dimensions and thermal traits—coupled with empirical energy usage and longitudinal meteorological records. The informational inputs necessitated by this approach are substantially less voluminous than those mandated by comprehensive, physics-driven energy simulations. The outcomes demonstrate the feasibility of precisely deploying the trained neural network to forecast conservation yields from targeted efficiency enhancements, validated against the projected usage of a localized residential sub-sample. Considering that the majority of municipalities in the US Midwest feature housing stocks exhibiting thermal variance akin to the evaluated sample—which realized a 36% efficiency gain at an LCFS beneath $14/mmBTU ($14,782/MJ)—the deployment of a “worst-to-first” mitigation framework demonstrates a profound capacity for substantial regional impact. For municipal planners and policymakers, these findings can serve as a foundational blueprint for formulating broader urban energy conservation directives. The robust conservation projections introduced in this study can instill greater certainty within financial decision-making paradigms regarding EE capital allocations. Although the granular data required to calibrate the proposed machine learning architectures is not currently in the public domain, significant potential exists to systematically aggregate this information via standard municipal property appraisals and routine residential inspections. Moreover, the exact analytical framework detailed in this investigation can be adapted to structure and prioritize future capital investments targeting the integration of renewable energy systems.
None
None
None
None
Open Access The author(s) retain copyright. This article is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. It may be shared and adapted for non-commercial purposes with appropriate attribution, an indication of changes, and distribution of adaptations under the same license. Third-party material may be subject to separate terms identified in its credit line. View the license at https://creativecommons.org/licenses/by-nc-sa/4.0/.